mirror of
https://github.com/SHOGGOTH-SECTOR/sica-fondt.git
synced 2026-08-01 08:30:20 +00:00
Place useful parts of the surrounding repos into sica-fondt by layer, per the
body model (Ada = membrane; brain/endocrine/capabilities/knowledge non-Ada):
- brain/ LLM reasoning + providers (dapr, hermes, MoMoA)
- capabilities/ REPRAG sidecars: hermes tools/skills, dapr tools, parallel
dispatch, A51 channels, and the OSINT cluster
- knowledge/ LORAG corpus: 754 cyber-skills, agency personas, secure-coding,
MITRE ATT&CK data
- reference/ defensive threat-reference (C3, shhbruh doc) + AdaYaml parser
License handling: AGPL sources (worldosint, advanced_evolution, mercury,
Reticulum) and GPL DeTTECT are SPEC-only clean-room/port descriptions — no
copyleft code copied. MIT/Apache/data parts copied as working trees.
Safety: shhbruh escape/persistence material and C3 covert-C2 kept as reference
only, not wired into the running organism. See CONSOLIDATION.md.
https://claude.ai/code/session_01UehUqEXXJJCsHoA4voCU5c
2.0 KiB
2.0 KiB
SCADA Attack Detection — API Reference
Libraries
| Library | Install | Purpose |
|---|---|---|
| pymodbus | pip install pymodbus |
Modbus TCP client for PLC interaction |
| requests | pip install requests |
SIEM and historian API queries |
Common SCADA Protocols and Ports
| Port | Protocol | Vendor/Use |
|---|---|---|
| 502 | Modbus TCP | Universal PLC communication |
| 102 | S7comm (ISO-TSAP) | Siemens S7 PLCs |
| 44818 | EtherNet/IP CIP | Allen-Bradley / Rockwell |
| 20000 | DNP3 | Power grid, water systems |
| 4840 | OPC-UA | Universal ICS integration |
| 47808 | BACnet | Building automation |
| 34962 | PROFINET RT | Siemens distributed I/O |
Modbus Attack Indicators
| Indicator | Description | Severity |
|---|---|---|
| Broadcast unit ID (0/255) | Access to all devices simultaneously | CRITICAL |
| Write to coils from IT network | Unauthorized process control change | CRITICAL |
| Unusual function codes (8, 17, 43) | Diagnostic/recon commands | HIGH |
| Bulk register reads | Data exfiltration from PLC memory | MEDIUM |
S7comm Connection Request (COTP CR)
| Field | Value | Description |
|---|---|---|
| TPKT version | 0x03 | ISO transport header |
| COTP PDU type | 0xe0 | Connection request |
| Source TSAP | 0x0100 | Client address |
| Destination TSAP | 0x0102 | PLC rack/slot |
MITRE ATT&CK for ICS
| Technique | ID | Description |
|---|---|---|
| Point & Tag Identification | T0861 | Enumerate process data points |
| Unauthorized Command Message | T0855 | Send rogue commands to controller |
| Modify Controller Tasking | T0821 | Change PLC program logic |
| Denial of Service | T0814 | Disrupt SCADA communications |